Wall Scanner Wall Detector PVC Water Pipe Metal Wood AC Cable Live Wire Finder

$29.49

Description
Name Value
Restocking Fee No
Return shipping will be paid by Buyer
All returns accepted Returns Accepted
Item must be returned within 30 Days
Refund will be given as Money Back
Brand Unbranded
Type Wall Scanner
Country/Region of Manufacture China
Item Weight 180g

WS120 Wall Scanner Multifunctional Wall Detector PVC Water Pipe Metal Wood AC Cable Live Wire Finder Scanner Diagnostic-tool Product Description: WS-120 Wall scanner Application: WS-120 is a handhold wall scanner for quick detection of magnetic metals in wall, rooftop and floor, such as reinforcing steels, iron pipes, and nonmagnetic metals such as aluminum pipes, copper pipes, and nonmetal materials such as beams, PVC water pipes, as well as electrified objects as live wires. Features: -Perfect for detecting metal, wood and AC cable hidden in the wall. -Indicates the detecting results by Light and Beep -Detect AC cable with voltage higher than 110V, 50-60Hz, the sensibility may be weak when the cable is grounded. -High accuracy, with a maximum detection depth of 110mm. Specifications: Detect Ferrous metal and Non-ferrous metal AC live wires, wood Maximum scanning depth: 110mm Ferrous metals: 110mm Non-ferrous metals (copper pipe): 110mm Copper conductors (live): 50mm Wood & PVC Tube : 25mm Automatic switch-off after approx: 5min Operating Condition : Temperature: -10 to 50C Humidity: <75% Altitude: <2000M Storage temperature: -20C to 70C General Information: Battery type: 3 * 1.5V, AAA alkaline (not included) Dimensions: 185*85*33mm Weight: 180g Package List: 1 * Wall Detector 1 * Carry Bag 1 * User Manual(English) Instructions for use 1、Switch on/off Short press the power on button to turn on, long press 3 seconds to turn off; When the power is turned on, the instrument will automatically initialize, the scale bar on the display window will rise to full state, and quickly fade into standby mode, if any button on the instrument is not operated within 3 minutes, or not detect any object, the detector will automatically shut down after 3 minutes. 2、Detection mode — automatic mode The measurement mode after power on is defaulted to automatic mode, you can also switch to automatic measurement mode through the button. In automatic mode, such as the detection of several substances at the same time, the order of the icon will be displayed in priority: charged → metal → magnetic → non-magnetic → non-metal. For example, the detection of metal and wood, the display will show the priority of metal objects icon. 3、Detection mode — metal mode Short button "work" into the metal mode for manual detection of magnetic, non-magnetic metal, not affected by the characteristics of the wall. 4, detection mode — AC line detection The instrument can only detect the voltage greater than 110V, 50 ~ 60Hz AC solid wire, twisted wire can not be detected 5、Recalibration When held in the hands of the detector near no metal objects, when the power is on or in metal mode, the scale bar full frame and red light, accompanied by an alarm tone, there may be environmental factors that produce interference, the above situation can be manually calibrated when the initialization of the detector. a) first detector do not stick to the wall, hold the detector in the air, hold the instrument's hand do not touch or cover the detection area of the shell I. b) such as in automatic detection mode short press a key, in metal mode short press a key, then the scale bar on the display window will rise to full state, and then quickly recede into the standby state, the initialization is over, the calibration is complete. c) Pay attention to the battery power, such as insufficient power will also produce the error phenomenon, the battery should have at least 1/3 of the power 6, use precautions 1, before opening the detector, you must make sure that there is no water on the detection area, if necessary, you have to dry with a cloth; do not let the moisture penetrate into the instrument, and do not let the sun shine directly on the instrument. 2, try to avoid not to expose the instrument to extreme weather, if the temperature difference between the measurement environment is relatively large, you need to wait for the temperature of the instrument and the ambient temperature is basically the same before use;. 3、When using the instrument for measurement, it is necessary to keep away from power tools or transmitting equipment, such as WLAN, UMTS, flying radar, transmitting towers or microwave ovens and other equipment with such characteristics. 4、When not using the instrument, please remove the battery from the instrument, so as not to corrode the battery compartment by leaving the battery for a long time. 5, environmental factors, may affect the measurement accuracy and depth of the instrument, such as the combination of wall composition (such as whether the building materials contain metal, whether the wall has conductive wallpaper, whether tile, whether there are sound-absorbing materials), the water content of the wall is relatively large and the number, type, size and location of hidden objects, etc., may cause mismeasurement and affect the accuracy. So when you drill, punch, saw, etc. in the wall before, first through other sources of information, good protection measures to prevent the danger. 6, keep the back of the instrument sensor window J parts of the clean, such as stained or blocked, the instrument will not be able to sense whether the wall. 7, if you want to find the wire, has been connected to the working state of the load (such as lights, appliances, etc.), you can more easily find the wire. In some cases may not be able to find the buried live wire, some wall objects will isolate the current, so the instrument can not detect the buried live wire. 8, static electricity may cause inaccurate detection results, in order to improve the detection results, you can put your empty hand flat against the wall next to the detection instrument, which can eliminate static electricity. 9, you can make a mark at the location where the hidden object is found. First detection, if you find the edge of the hidden object or the center point, and then from the mark hole A at the above location to mark 10、The detection instrument is equipped with a temperature monitoring device. Only the temperature inside the detection instrument can be kept constant to ensure accurate detection results. If there is a warning pattern 7, the temperature of the detector is outside the working temperature range, or the detector is exposed to a temperature difference in the environment. Turn off the detector and allow the instrument to return to normal temperature before turning on the instrument.

Reviews 0

There are no reviews yet.

Add a review

Be the first to review “Wall Scanner Wall Detector PVC Water Pipe Metal Wood AC Cable Live Wire Finder”

Your email address will not be published. Required fields are marked *

Updating…
  • No products in the cart.